Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1961 1
1970 2
1972 2
1977 2
1978 1
1980 1
1981 1
1982 5
1983 1
1984 7
1985 2
1986 4
1987 2
1988 1
1989 7
1990 6
1991 4
1992 8
1993 6
1994 4
1995 3
1996 7
1997 5
1998 5
1999 11
2000 14
2001 15
2002 11
2003 17
2004 26
2005 21
2006 29
2007 32
2008 30
2009 29
2010 31
2011 34
2012 25
2013 37
2014 38
2015 60
2016 48
2017 48
2018 50
2019 58
2020 59
2021 60
2022 64
2023 50
2024 18

Text availability

Article attribute

Article type

Publication date

Search Results

921 results

Results by year

Filters applied: . Clear all
Page 1
Biotensegrity or Fascintegrity?
Bordoni B, Varacallo MA, Morabito B, Simonelli M. Bordoni B, et al. Cureus. 2019 Jun 3;11(6):e4819. doi: 10.7759/cureus.4819. Cureus. 2019. PMID: 31404386 Free PMC article. Review.
The concept of cellular transduction is reviewed as it is the key to understanding if the passage of different mechanical information occurs only through solid structures, such as the cytoskeleton, or even liquid and viscous. The article focuses on reviewing the weaknesses …
The concept of cellular transduction is reviewed as it is the key to understanding if the passage of different mechanical information occurs …
Stress auto-correlation tensor in glass-forming isothermal fluids: From viscous to elastic response.
Maier M, Zippelius A, Fuchs M. Maier M, et al. J Chem Phys. 2018 Aug 28;149(8):084502. doi: 10.1063/1.5044662. J Chem Phys. 2018. PMID: 30193479
We develop a generalized hydrodynamic theory, which can account for the build-up of long-ranged and long-lived shear stress correlations in supercooled liquids as the glass transition is approached. ...In the fluid, anisotropic shear stress correlation …
We develop a generalized hydrodynamic theory, which can account for the build-up of long-ranged and long-lived shear stress co …
A comparative study on the analysis of hemodynamics in the athlete's heart.
Gülan U, Rossi VA, Gotschy A, Saguner AM, Manka R, Brunckhorst CB, Duru F, Schmied CM, Niederseer D. Gülan U, et al. Sci Rep. 2022 Oct 5;12(1):16666. doi: 10.1038/s41598-022-20839-8. Sci Rep. 2022. PMID: 36198719 Free PMC article.
To characterize the intracavitary blood flows in the right ventricle (RV) and right-ventricular outflow tract (RVOT) in 2 healthy probands, patients with arrhythmogenic right ventricular cardiomyopathy (ARVC) and 2 endurance athletes, we performed 4D-MRI flow measurements to asse …
To characterize the intracavitary blood flows in the right ventricle (RV) and right-ventricular outflow tract (RVOT) in 2 healthy probands, …
Magnetohydrodynamic levitation for high-performance flexible pumps.
Matia Y, An HS, Shepherd RF, Lazarus N. Matia Y, et al. Proc Natl Acad Sci U S A. 2022 Jul 19;119(29):e2203116119. doi: 10.1073/pnas.2203116119. Epub 2022 Jul 11. Proc Natl Acad Sci U S A. 2022. PMID: 35858310 Free PMC article.
The magnet piston is kept concentric within the tube by Maxwell stresses within the ferrofluid and magnetohydrodynamic levitation, as viscous lift pressure is created due to its forward velocity. The centering of the magnet reduces shear stresses durin …
The magnet piston is kept concentric within the tube by Maxwell stresses within the ferrofluid and magnetohydrodynamic levitation, as …
Finite-difference and integral schemes for Maxwell viscous stress calculation in immersed boundary simulations of viscoelastic membranes.
Li P, Zhang J. Li P, et al. Biomech Model Mechanobiol. 2020 Dec;19(6):2667-2681. doi: 10.1007/s10237-020-01363-y. Epub 2020 Jul 3. Biomech Model Mechanobiol. 2020. PMID: 32621160
The twisting sphere tests confirm that, compared to the numerical errors induced by other components in capsule simulations, such as the finite element method for membrane discretization and IBM for flow-membrane interaction, the errors from the viscous stress calcu …
The twisting sphere tests confirm that, compared to the numerical errors induced by other components in capsule simulations, such as the fin …
Bicuspid aortic valve disease is associated with abnormal wall shear stress, viscous energy loss, and pressure drop within the ascending thoracic aorta: A cross-sectional study.
Geeraert P, Jamalidinan F, Fatehi Hassanabad A, Sojoudi A, Bristow M, Lydell C, Fedak PWM, White JA, Garcia J. Geeraert P, et al. Medicine (Baltimore). 2021 Jul 2;100(26):e26518. doi: 10.1097/MD.0000000000026518. Medicine (Baltimore). 2021. PMID: 34190185 Free PMC article.
Locations were analyzed for aortic diameter (normalized to body surface area), pressure drop (PD), viscous energy loss (EL), and wall shear stress (WSS) sub-vectors (axial wall shear stress, circumferential wall shear stress [WSSC] …
Locations were analyzed for aortic diameter (normalized to body surface area), pressure drop (PD), viscous energy loss (EL), and wall …
On the examination of the viscous response of the brachial artery during flow-mediated dilation.
Sidnawi B, Santhanam S, Sehgal C, Wu Q. Sidnawi B, et al. J Mech Behav Biomed Mater. 2022 Jul;131:105255. doi: 10.1016/j.jmbbm.2022.105255. Epub 2022 Apr 27. J Mech Behav Biomed Mater. 2022. PMID: 35500495
Experimental BAFMD responses were collected from 12 healthy volunteers. The arterial wall's elastic and viscous properties were treated as local variable quantities depending on the wall shear stress (WSS) sensed by mechanotransduction. ...Among those dimensi …
Experimental BAFMD responses were collected from 12 healthy volunteers. The arterial wall's elastic and viscous properties were treat …
A relationship between Reynolds stresses and viscous dissipation: implications to red cell damage.
Jones SA. Jones SA. Ann Biomed Eng. 1995 Jan-Feb;23(1):21-8. doi: 10.1007/BF02368297. Ann Biomed Eng. 1995. PMID: 7762879 Review.
Viscous shearing is examined as a mechanism by which turbulent flows can cause cellular damage. ...It is shown that under simple flow conditions the Reynolds stresses can be related to viscous dissipation. Data from the literature show that the instant
Viscous shearing is examined as a mechanism by which turbulent flows can cause cellular damage. ...It is shown that under simp
The effect of turbulent viscous shear stress on red blood cell hemolysis.
Yen JH, Chen SF, Chern MK, Lu PC. Yen JH, et al. J Artif Organs. 2014 Jun;17(2):178-85. doi: 10.1007/s10047-014-0755-3. Epub 2014 Mar 12. J Artif Organs. 2014. PMID: 24619800
Non-physiologic turbulent flow occurs in medical cardiovascular devices resulting in hemodynamic stresses that may damage red blood cells (RBC) and cause hemolysis. Hemolysis was previously thought to result from Reynolds shear stress (RSS) in turbulent flows …
Non-physiologic turbulent flow occurs in medical cardiovascular devices resulting in hemodynamic stresses that may damage red blood c …
Wrinkling and folding of thin films by viscous stress.
Chatterjee S, McDonald C, Niu J, Velankar SS, Wang P, Huang R. Chatterjee S, et al. Soft Matter. 2015 Mar 7;11(9):1814-27. doi: 10.1039/c4sm02501f. Soft Matter. 2015. PMID: 25611394
Releasing the prestretch in the rubber induces a viscous stress in the liquid, which in turn induces a compressive stress in the elastic film, leading to buckling. Unlike many previous studies on wrinkling of floating films, the buckling process in the presen …
Releasing the prestretch in the rubber induces a viscous stress in the liquid, which in turn induces a compressive stress
921 results